How to wire 2 gfci outlets together - This procedure requires GFCI outlet wiring in series, and provides protection to any additional outlets (including standard outlets) "downstream" on the same circuit. Multiple-location wiring requires two circuit cables in the electrical box—one for power coming into the outlet (marked with the word LINE on the backside) and one for power ...

 
Press the T (Test) button to make the GFCI breaker trip. It does this by allowing a small current to bypass its toroid coil. Press the R (Reset) button to restore power to the GFCI breaker. If it doesn’t have a reset button, reset it by flipping the switch manually to the ON position.. Does fryd have pesticides

Birkenstock is a popular German footwear brand that has been around since 1774. The company has become well-known for its comfortable and stylish sandals, clogs, and other shoes. T...Wiring 2 Gfci Outlets Together 02 Jan 2024. Gfci outlets wiring gfi receptacles electrical leviton interrupter fault receptacle chanish Gfci wiring electrical load outlet outlets receptacle split protected switch standard plug light diagrams installation installing basic these will make Gfci installation outlets diagrams solar 55kb projects gfi.In this video, I'll show you how to properly wire and install a GFCI (Ground Fault Circuit Interrupter) outlet. GFCI receptacles are important to have in a s...Step 2. Find the terminal screws and expose them by pulling the outlet out from the box. Wire test the outlet with a multimeter to ensure it is not powered. Hold the multimeter and press all the black wires against the black probe’s tip. Also, press all the white wires against the white probe.Wiring a GFCI Outlet and Light Switch. This wiring show the connections for a gfci outlet switch combo used to control an unprotected light fixture. Here, the source hot wire is spliced to the LINE hot terminal on the combo and one of the builtin switch wires. A 2-wire cable runs from the GFCI device to the light fixture and the black wire is ...You will not be able to use the "load" terminals to connect wires as those will cut out when the GFCI does. The best way to do this is to wire-nut the line and load wires together (hot separate from neutral of course) along with a third piece of insulated wire to connect to …I'm replacing a the middle outlet/receptacle on a non-GFCI circuit with two receptacles and I can't for the life of me figure out why the neutral wires are swapped on the middle receptacle. ... Use a wire nut to connect the two hot wires together with a short black (or red or blue or yellow) wire and connect that short wire to either screw ...Once the power is off, begin by connecting the wires to the GFCI outlet. The black wire should be connected to the brass screw, and the white wire should be connected to the silver screw. It's important to note that any additional outlets you're wiring should also have a black and white wire attached. Next, run a pigtail wire from each of ...Wiring a GFCI Outlet: Connect the black wire to the line row’s brass terminal. Attach the white wire to line the row’s silver terminal. Connect the ground wire to the ground terminal. Repeat steps 1-3 for the second load cable on the load row. Combine all ground wires. Connect combined grounds to the ground terminal.GFCI stands for Ground Fault Circuit Interrupter, and it's designed to protect people from electric shock by monitoring the amount of current flowing through an electrical circuit and sensing if any of that current is lost or leaking. By connecting two GFCI outlets together, you create a much safer and more reliable circuit than a traditional ...All black wires should be connected to live (known as hot) terminals. All white wires should be connected to neutral terminals. All green or bare wires should be connected to ground terminals. We’ll dive into the nuts and bolts of wiring up that GFCI outlet with others, ensuring your home is safer and more functional.Attach the black wire to the brass screw on the terminal marked 'Hot' or 'Black.'. Attach the white wire to the silver screw on the terminal marked 'Neutral' or 'White.'. Attach the ground wire to the green screw on the terminal marked 'GRD' or 'Ground.'. Use nose pliers if you need to wrap a wire around its terminal.What you do need to do, however, is make sure you connect the new outlet to the LOAD terminals on the GFCI outlet. That will put the new outlet on GFCI protection. You should also sticker the new outlets as GFCI protected. See in the above how the duplex (standard) outlet is fed from the GFCI, NOT the main line.How To Wire A GFCI And Receptacle. In this video I will show you how to wire up a GFI and make a receptacle GFI protected. This will save you money and it so...Bremerton, Washington. Mar 17, 2021. #10. You are not allowed to connect the EGC when using 12/2 or 14/2 downstream of a GFCI. See 406. 4 D. You must mark the downstream receptacle "GFCI Protected" and "No Equipment Ground" The this section states, An EGC shall not be connected between the grounding type receptacles.As was mentioned before, it is cheaper to use one GFCI receptacle to protect multiple outlets. If you have dozens of outlets in a large building, it would cost you a lot of money to install a GFCI receptacle at each outlet. 2). Convenience . Even though the installation of GFCI receptacles in series is cheaper, the configuration is also ...Wiring a GFCI Outlet and Light Switch. This wiring show the connections for a gfci outlet switch combo used to control an unprotected light fixture. Here, the source hot wire is spliced to the LINE hot terminal on the combo and one of the builtin switch wires. A 2-wire cable runs from the GFCI device to the light fixture and the black wire is ...I'm replacing a the middle outlet/receptacle on a non-GFCI circuit with two receptacles and I can't for the life of me figure out why the neutral wires are swapped on the middle receptacle. It appears to be deliberate as the 12 ga wire is bent to create a criss-cross pattern. This was installed by a DIY-er so to me this would seem deliberate.How to replaced a GFCI / GFI outlet correctly is today's video tutorial. The outlet we are working on today is a GFCI with 4 wires. I will show you the prope...This means that all the outlets, wires, and other components connected to the same circuit must have their own GFCI. This can be accomplished by using one GFCI device at the beginning of the circuit, or by installing multiple GFCIs along the circuit. Additionally, GFCI devices must be properly wired in parallel in order to be effective.Start by unscrewing the GFCI outlet. It should have two wires – a black one and a white one. The ground wire should be black. Connect the two together before installing the GFCI outlet in the wall. Depending on how many outlets are in the circuit, you can wire them in parallel or series.Most of it has had the wiring upgraded. However, I have one room with multiple outlets that are all ungrounded with the original cloth covered wiring. There is only one pair of wires (1 black, 1 white) coming out of each outlet on the circuit. I want to add a single GFCI outlet to the first receptacle in the circuit to provide ground fault ...Are you looking to wire outlets in series or parallel? In this video, we're going to show you the differences between series and parallel wiring, and explain...Knowing a little about Ground Fault Current Interrupt (GFCI) outlets can help you troubleshoot one of the most common sources of electrician service calls in...OK I'll make another suggestion (let me know if you're comfortable with this): Turn breaker off. Temporarily connect all the 3 whites (neutrals) together*, and all 3 blacks together. Turn the breaker on. Confirm everything works. *you can do this by twisting a wire nut on without first twisting the wires together.Jan 5, 2022 · A 2-pole (240V), 20A GFCI breaker, feeding a MWBC (Multi-Wire Branch Circuit) via 12/3 cable. To a single receptacle with the hot side "split" and fed from each hot wire. Two individual 20A GFCI breakers, with a handle-tie, placed adjacent since the handle-tie requires it. Dual 12/2 cable running to the receptacle. Start by unscrewing the GFCI outlet. It should have two wires – a black one and a white one. The ground wire should be black. Connect the two together before installing the GFCI outlet in the wall. Depending on how many outlets are in the circuit, you can wire them in parallel or series.I am guessing the outlets on the back splash are daisy chained together, as there are 3 in a row. One to the left of the stove one to the right of the stove and one farther to the right. We wanted to replace the single outlet on the left of stove, single gang, with a new GCFI outlet as well.1. I have installed a single toggle switch/outlet on a GFCI circuit and the outlet is fine, however, the toggle switch for 3 recessed led lights trips the GFCI. It a Remodel. I have run 12/3 w/grd from source to a gfci outlet. In the circuit is a switch/outlet.How to wire GFCI and regular receptacles in series, down stream properly.Wire Outlets (receptacles) in sequence. Learn to wire the beginning/middle (same) outlets, and the final outlet of the cable run. Wiring diagrams are embed...Amazon Prime Free for 6 months for students. Then, enjoy Prime at half the price, just $7.49/month: https://amzn.to/3NsFy7Q Audible Plus Free for 1 month + 2...When you need to wire multiple GFCI outlets such as in a kitchen or bathroom you have a couple of options. To save money, you can put in a single GFCI and then wire additional standard outlets to the "LOAD" output from the single GFCI. This provides the same protection as having a GFCI at each location. The downside is in going this route if ...In this video, This Old House master electrician Heath Eastman teaches host Kevin O'Connor everything he needs to know about ground fault circuit interrupter...If you have an outlet that you would like to use to power an additional outlet then that can be accomplished with a process called "daisy-chaining". This is ...Are you looking to wire outlets in series or parallel? In this video, we're going to show you the differences between series and parallel wiring, and explain...Web when you need to wire multiple gfci outlets such as in a kitchen or bathroom you have a couple of options. Web i show how to wire a gfci outlet with 2 wires going to the gfci. Source: annawiringdiagram.com. Web having two gfci outlets connected together can provide you with the convenience of having two separate power. Web how to wire a ...Leave the ground terminal disconnected. Replace the outlet and put a label on it that reads "No Equipment Ground." This label is usually supplied with the outlet, and it warns people against relying on the outlet for surge protection. You can wire a three-prong outlet to the GFCI by connecting it to the LOAD terminals.Overall, wiring multiple GFCI outlets on the same circuit is a bit more complicated than wiring regular outlets. However, with the right tools and a bit of patience, it's a manageable task. ... Can two GFCI outlets be wired together? While it is technically possible to wire two GFCI outlets together, it is not recommended as it can lead to ...So the wire from the junction box to the panel is new, but from the box to the outside receptacle is older white romex. It goes though the top of my foundation, and through the crawlspace in the back porch before it gets to the outlet. When I got home last night i was in the yard and i heard the GFCI trip. so I checked the new breaker and it ...The first floor half-bath and the second-floor full bathroom outlets are on the same circuit. The lights and fans of both bathrooms are on another circuit entirely. This line appears to run just up the wall and power the both bathroom outlets only. This NEC set of rules says that all bathroom outlets must be GFCI.Add an inch for all the grounding wires together, Add an inch for all the cable clamps together, Add two inches for each device (outlets or switches). If the wire is 14-gauge, simply doubling the total will give you the required box size in cubic inches. As for a 12-gauge wire, you’ll want to multiply the total by 2.25.Step 2: Combine and Connect the Ground Wires. Combine the two ground wires using a wire cap or connector. Curl the end of the ground wire sticking out, using nose pliers, to form a hook and connect it to the green screw of the outlet's ground terminal. Video | HandyDadTV.Turn on the Power and Test. Once you're satisfied, go back to the electrical panel and turn on either the circuit breaker you turned off earlier or the main breaker, if that's what you used. Go to the new GFCI outlet and press the reset button. Now use your tester to check the circuit.The two GFCIs will not interrupt one another. Some people are convinced that plugging one GFCI into another will cause one of the GFCIs to interfere with the functions of the other one. As a result, when a ground fault occurs, neither GFCI will respond, exposing the homeowner to the threat of electrocution. But that couldn’t be further from ...In other words, the outlet in GFCI can be turn ON/OFF via upper switch in the GFCI combo. To do this, simply connect the upper wire (there are two builtin wires on the back side of GFCI) to the line terminal of GFCI while the second wire should be wired to the incoming line (phase, live or hot) wire. There's simply no way to do it. You only have two receptacle sites per MWBC. The whole point of an MWBC is to make good use of both hot legs. Well, you need two GFCI+receptacle devices to do that. And that fills both sites. So the issue of extending off the LOAD terminals of one of the GFCI+receptacles will never come up. 1. Turning Off the Power. The first and most crucial step to not only wiring a GFCI outlet with 4 wires, but installing any electrical component is to completely shut off any power that it is connected to. This can be done with the help of a local circuit breaker or the main breaker. Whichever is more convenient for the installation.The downside of this is that 2-pole GFCI breakers are expensive. It may be cheaper to wire one GFCI outlet on each circuit and wire the rest of the outlets on the load of the corresponding GFCI outlet using 12/2 cable. The 2-pole GFCI breaker is as expensive as about seven individual GFCI outlets. It will also be more convenient to reset the ...In 10 minutes I show you how I changed an old outlet to a GFCI outlet, with an accompanying light switch. I am not an electrician, just an amateur, but it wo...GFCIs operate by sensing the amount of current is being used by a device. The device looks for the same amount of current coming into the device and back out of the device. If the amount of current drops on the return side of the device, the GCFI will sense an imbalance (typically caused by a short of some sort) and trip the outlet off.Wiring a GFCI Outlet and a Light Switch. This diagram illustrates wiring a GFCI receptacle and light switch in the same outlet box, a common arrangement in a bathroom with limited space. The hot source is spliced to the LINE terminal on the receptacle and to one terminal on the light switch. The neutral and ground wires are spliced together and ...Home. Wiring Diagram. how to connect 2 gfci outlets together. How To Connect 2 Gfci Outlets Together. By Wiring Work | March 10, 2020. 0 Comment. …Wiring A Light Switch And 2 Outlets Together Diagram. By Wiring Digital | July 27, 2022. 0 Comment. Light switch wiring diagrams for household switches outlet wire imglvl how to a 3 way diy family handyman switched archives page 2 of electrical online do i connect gfci single pole wall it yourself help com rewire that controls an control ...GFCI stands for Ground Fault Circuit Interrupter, and it's designed to protect people from electric shock by monitoring the amount of current flowing through an electrical circuit and sensing if any of that current is lost or leaking. By connecting two GFCI outlets together, you create a much safer and more reliable circuit than a traditional ...Quick Summary to wire a GFCCI outlet with multiple outlets: Multiple outlets can be connected to a GFCI outlet in a parallel arrangement. The line terminals of the additional outlets are connected to the load terminals of the primary outlet. The line terminals of the main source GFCI outlet are connected to the main electricity supply. Wiring a GFCI Outlet and a Light Switch. This diagram illustrates wiring a GFCI receptacle and light switch in the same outlet box, a common arrangement in a bathroom with limited space. The hot source is spliced to the LINE terminal on the receptacle and to one terminal on the light switch. The neutral and ground wires are spliced together and ... That means up to eight GFCI+receptacles. Option 2 is fit a 2-pole GFCI breaker, and wire the circuit in the normal way you intended, but with normal outlets. DONE. This works because the entire MWBC complex is inside the GFCI protected zone, so you can do all the normal MWBC things therein. A 2-pole GFCI breaker is typically $80. Option 3 is to ...The line connection is used for all GFCI outlet installations. The circuit's hot wire (typically colored black or red) connects to the black or brass-colored screw terminal marked LINE. The white neutral wire connects to the silver-colored screw terminal marked LINE. The markings for line and load usually are printed on the back of the outlet's ...Pierre. is not the white (neutral) conductor that is connected to the 2 pole GFCI breaker necessary for the breaker circuitry to operate properly. The neutral pigtail is not for the operation of the breaker as the GFCI circuit does not need a referance to ground. if there was 120 volts being used then yes as the neutral would have to be ...Testing the initial GFCI receptacle should be sufficient. No need to test the load side receptacles since they are protected by the GFCI. If the GFCI works, and the 2 prong receptacles are connected to the load side of the GFCI, then they are protected. If however, you wish to pursue it, you would need a separate conductor run to a good ground.Install the new ground-fault circuit interrupter outlet by attaching both the black and white wires to the "line" side of the outlet. Connect the bare wire to the grounding screw. Replace the cover plate, then check to make sure the GFCI is operating properly. Press the test button; the outlet should go dead. Reset to resume current flow.Aug 9, 2021 · My kids bathroom GFCI outlet box has two 2-wire romex cables coming in. One was wired to load, other to line, ground tied. With some testing using a NCV tester, I find that both cables are hot The "line" wire is hot when breaker #4 is on; The "load" wire is hot when breaker #6 is on; I wired my new GFCI outlet to breaker #4 Phase 1: Initial Steps (Pre-Wiring) Firstly, ensure you can identify the LINE and LOAD rows for the hot/live and neutral terminals on the GFCI outlets. For personal safety, you must turn the power off to the circuit before starting. Switch off the circuit breaker for the circuit you will be working on.Step 2. Remove the old receptacles and save them for reuse. Using the hacksaw, cut the nails securing the old device boxes to the studs and pull them from the wall. Leave the first one attached to the home run cable, the cable running back to the service panel so it doesn't slip down inside the wall cavity.Connect the hot wire from the GFCI outlet to the hot wire from the switch. Use a wire nut to connect the two wires together. 7. Connect the neutral wire from the GFCI outlet to the neutral wire from the switch. Use a wire nut to connect the two wires together. 8.How to Wire a GFCI Outlet: Step-By-Step. Replacing 2-Prong Outlets With GFCI and Wiring GFCI in a Series. By. Bob Formisano. Updated on 11/02/23. Reviewed …It's easy to install a Leviton GFCI outlet.The Reset Lockout feature prevents reset if a Leviton SmartlockPro GFCI Outlet or AFCI Outlet is damaged so that i...Here I will break down how the wiring of a standard wall outlet works and how/where GFCI outlets should be installed.I also go over some of the tools needed ...Step 2. Remove the old receptacles and save them for reuse. Using the hacksaw, cut the nails securing the old device boxes to the studs and pull them from the wall. Leave the first one attached to the home run cable, the cable running back to the service panel so it doesn't slip down inside the wall cavity.A: The "line" refers to the set of terminals where the power supply is connected, while the "load" refers to the set of terminals where additional outlets or devices are connected downstream from the GFCI outlet. Q: How do I test GFCI outlet wiring? A: To test a GFCI outlet, simply press the test button on the outlet.The 4 wires in a GFCI outlet are the black wire (hot), the white wire (neutral), the bare copper wire (ground), and the red wire (additional hot wire). The black and red wires are used for connecting to separate circuits or for connecting to a multiwire branch circuit.%PDF-1.6 %âãÏÓ 1 0 obj >/Metadata 469 0 R/AcroForm 470 0 R/Pages 2 0 R/Type/Catalog>> endobj 469 0 obj >stream uuid:25d6dd06-2030-4dd4-8046-2e2a44148ff2 adobe:docid:indd:1e18c5e9-8775-11db-b3c1-cf3e21ebb38d proof:pdf 1e18c5e8-8775-11db-b3c1-cf3e21ebb38d adobe:docid:indd:50d90505-850e-11db-a9df-fb2b346505d7 ReferenceStream 72.00 72.00 Inches ...Learn how to wire a pigtail connection for an outlet with this easy-to-follow video tutorial. You will see how to connect the wires, strip the insulation, and secure the pigtail with a wire nut ...In a short circuit, the hot and neutral wires touch, while in a ground fault, the hot wire touches the ground. Both short circuits and ground faults will result in blown fuses and circuit or circuit breakers respectively. If a ground fault happens, your GFCI outlet will act as an alert but in a short circuit, you may be alerted by smoke or sparks.Once you have confirmed that the circuit is dead, you can begin wiring the GFCI outlet. Start by removing the cover from the GFCI outlet and connecting the insulated stranded wire to the terminals on the side of the outlet. Make sure that the wire is securely connected to the terminals. Next, connect the other end of the wire to the ground ...1. Identify the "LOAD" and "LINE" sections on the back. Every GFCI outlet has 4 terminals for wires. Two of these terminals sit on either side of the "LINE" indicator at the bottom, and two of them sit on either side of the "LOAD" indicator at the top. There is also a green screw at the bottom for the grounding wire.Shopping at a Bloomingdale outlet store can be a great way to save money on designer clothing and accessories. But before you head out to the store, there are a few things you shou...Connect the bare ground wire to the green (Ground) screw. ( See Diagram A ). Replace the receptacle, screw it back into the box, and attach the cover plate. Turn the power back on at the circuit-breaker panel. Plug a clock radio or light into the outlet. Test the GFCI by pressing the Black "Test" button on the outlet.Nov 27, 2022 · Step 2. With the wires twisted together and secured with wire nuts, insert them into the side terminals of the GFCI outlet. The black wires go on the brass screws, and the white wires go on the silver screws. If there is a green grounding wire, it will go on the green grounding screw. The white and ground go to the neutral bar. From my reading here, I know that this is a multi-wire branched circuit. Also from my reading, it looks like to properly protect the 2 bathrooms, I have two options: 1) Install a 2-pole 15A GFCI 240V breaker ($90, but easier) 2) Install 15A GFCI outlets on all outlets ($25-$40, but more involved)

Updated on February 17, 2024. There are several different reasons why a GFCI keeps tripping. The most common reason is water or moisture that has gotten into the receptacle box or outlet. However, a tripping GFCI device could also get caused by an overloaded circuit, a malfunctioning outlet, electrical issues, or improper installation.. Mline trolley tracker

how to wire 2 gfci outlets together

The only way to use two GFCI receptacles to provide GFCI protection to more than two total receptacles on a shared-neutral circuit is to stop sharing the neutral after the GFCIs - by using two seperate 12/2's, or 12/2/2. You can still use 12/3 to feed the first set (the GFCIs), but will need to immediately end the 12/3 after the first GFCI.Step 2: Install the first GFCI outlet. Start by installing the first GFCI outlet at the beginning of the circuit. Remove the cover plate, unscrew the existing outlet, and disconnect the wires. Connect the wires to the corresponding terminals on the GFCI outlet using a …Connect the bare ground wire to the GFCI outlet’s green screw. Replace the GFCI outlet back into the box, carefully folding the wires inside. 5. Switch On the Power and Test the GFCI Outlet. Switch the power back on to the GFCI unit. Plug in a lamp to make sure that the power is back on. If not, press the red button to restore the power.Wiring a GFCI Outlet and a Light Switch. This diagram illustrates wiring a GFCI receptacle and light switch in the same outlet box, a common arrangement in a bathroom with limited space. The hot source is spliced to the LINE terminal on the receptacle and to one terminal on the light switch. The neutral and ground wires are spliced together and ...First, connect the black wire from the electrical box to one of the two brass terminals on the GFCI outlet. The remaining brass terminal should be connected to the red wire. Connect the white wires from both the GFCI outlet and the electrical box together using a wire connector. Connect the green or bare copper ground wire from the GFCI outlet ...%PDF-1.6 %âãÏÓ 1 0 obj >/Metadata 469 0 R/AcroForm 470 0 R/Pages 2 0 R/Type/Catalog>> endobj 469 0 obj >stream uuid:25d6dd06-2030-4dd4-8046-2e2a44148ff2 adobe:docid:indd:1e18c5e9-8775-11db-b3c1-cf3e21ebb38d proof:pdf 1e18c5e8-8775-11db-b3c1-cf3e21ebb38d adobe:docid:indd:50d90505-850e-11db-a9df-fb2b346505d7 ReferenceStream 72.00 72.00 Inches ...Wiring a 220-volt outlet begins with installing a suitable breaker switch. Then, wires are run from the breaker box to the desired location, where they are attached to a receptacle...Step 2. With the wires twisted together and secured with wire nuts, insert them into the side terminals of the GFCI outlet. The black wires go on the brass screws, and the white wires go on the silver screws. If there is a green grounding wire, it will go on the green grounding screw.The first floor half-bath and the second-floor full bathroom outlets are on the same circuit. The lights and fans of both bathrooms are on another circuit entirely. This line appears to run just up the wall and power the both bathroom outlets only. This NEC set of rules says that all bathroom outlets must be GFCI.Dec 26, 2023 · To wire two GFCI outlets together, you will need two GFCI outlets, two 12-gauge wires, a wire nut, and a screwdriver. The first step is to turn off the power to the circuit that you are working on. Next, connect the black wire from the first GFCI outlet to the black wire from the second GFCI outlet. Aug 5, 2019 ... In this video, I show how I remove an existing 120V outlet (receptacle/plug) and replace it with a GFCI protected outlet. In the video, I do ...Two 20 amps gfci outlets used for kitchen back splash. Double gang outlet conversion!How to wire switches: this is the traditional way of adding a new light Wiring outlet diagram electrical gfci box multiple switch wire outlets receptacles circuit diagrams house series receptacle gang wall parallel power.. Double Gang Outlet Conversion! - …Things You Should Know. Disconnect the fuse for the outlet you’re replacing before you work on the outlet. Remove the faceplate, …1. I'm trying to install a GFCI outlet, but the outlet being replaced used two neutrals, one hot, and a ground wire. I've only seen instructions on how to wire either only the LINE side (with one hot, one neutral) or the LINE and the LOAD (two of each).wiring a gfi receptacle and 2 switches in a 2 gang box consult with codes before doing electrical workWiring Two Gfci Outlets In One Box 03 Oct 2023. Wiring diagram ground fault receptacle Gfci outlet wiring diagram Gfci outlet wiring diagram amp electrical wire outlets receptacle switch nm type ground light circuits installation schematic problems basic multiple. ... ← Wiring Stop Start Buttons Wiring Two Gfci Outlets Together ...My kids bathroom GFCI outlet box has two 2-wire romex cables coming in. One was wired to load, other to line, ground tied. With some testing using a NCV tester, I find that both cables are hot The "line" wire is hot when breaker #4 is on; The "load" wire is hot when breaker #6 is on; I wired my new GFCI outlet to breaker #4Introduction:In residential electrical installations, it is common to have a combination of outlets and light switches in close proximity. When it comes to e....