Carrier 48fc 15 ton - 14 = 12.5 Ton C = Temp Standard Leak Econo w/PE(cent) ---17 = 15 Ton Vertical Only 20 = 17.5 Ton E = Enthalpy Standard Leak Econo w/Baro relief 24 = 20 Ton F = Enthalpy Standard Leak Econo w/PE(cent) 26 = 23 Ton --- Vertical Only N = Temp Ultra Low Leak Econo w/ baro relief Sensor Options P = Temp Ultra Low Leak Econo w/PE vert only

 
Carrier’s WeatherMaker® 15 to 27.5 ton rooftop unit (RTU) was designed by customers for customers. With “no-strip” screw collars, handled access panels, and more, we’ve made your unit reliable and easy to install, maintain, and use. Easy to install These WeatherMaker units are designed for dedicated factory-sup-. Movies santa clarita

Single Package Rooftop Units Gas Heating/Electric Cooling Select 12.5 to 27.5 Ton Flue Discharge Deflector Accessory. Brand: Carrier | Category: Air Conditioner | Size: 0.33 MB. Carrier 48FC Series Pdf User Manuals. View online or download Carrier 48FC Series Installation Instructions. Carrier 48FC 6 Ton Gas/Electric 14 SEER Packaged Rooftop Unit 460-3-60 MED Static. Spring 2024 Preseason is going on now. ... SEERs up to 14.0, IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F …Performance Features. 38AUQ Heat Pump EERs up to 11.0 and 3.5 COP. ASHRAE 90.1 Efficiency Compliant. Standard crankcase heater. Compressor vibration isolation. Low ambient temperature control. Unit performance certified in …Puron Refrigerant is Carrier’s unique refrigerant designed to help protect the environment. Puron is an HFC refrigerant which does ... Ratios) of 15.0 to 16.0, 12.0 to 12.5 EER, and AFUE (Annual Fuel Utilization Efficiency) ratings as high as 81%. ... ton). Coupled with the improved dehumidification associated with 12.5 TON High Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. ... 48fc-8-14-01si; Specifications. Brand Carrier; BTU Input 250000; CarrierRestore set-points for thermostat and humidistat (Y/N) _____. 2021 Carrier. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs …Up to 15.6 SEER, 13.0 IEER, and 12.2 EER. Gas efficiencies up to 82%. Standard cooling operating range up to 125 °F (52°C) and down to 35°F (2°C). Low ambient controllers can bring cooling operation down to -20°F (-29°C) Innovative non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center ...30 to 100 Nominal Tons. 48P2 – Vertical CV/SAV. 48P3 – Vertical VAV. 48P4 – Horizontal CV/SAV. 48P5 – Horizontal VAV. Carrier P Series rooftop units are pre-wired and factory-tested in both cooling and heating modes. All models feature an industrial grade cabinet with fully hinged access panels.Carrier West Training – HVAC TrainingCarrier The Carrier rooftop unit (RTU) was designed by customers for customers. With "no-strip" screw collars, handled access panels, and more the unit is easy to install, easy to maintain, and easy to use. Your new 3 to 6 ton WeatherMaker Carrier rooftop unit (RTU) provides optimum comfort and control from a packaged rooftop. Value-added features include: Are you in the market for a half ton towable fifth wheel? If so, you’re in luck. There are plenty of great options out there to choose from. But with so many different models and f...Carrier 48FC Series Controls, Start-Up, Operation And Troubleshooting (144 pages) Single package rooftop units with systemvu controls version 1.x and puronr (r-410a) refrigerant. Table of Contents General. Manual is suitable for 4 more products: 48GC Series 48GC 05 48GC 04 48GC 06. Brand: Carrier | Category: Air Conditioner | Size: 4.05 MB.American Airlines is ending the AirPass program, which offered fixed rates for travel and a ton of lucrative perks. While most travelers purchase airline tickets directly from the ... A Pg 1 11-22 Replaces: 48FC-8-14-01SB. 48FC 08-16 size units are single-packaged electric cooling, gas heating units that are pre-wired and pre-charged with Puron® (R-410A) HFC refrigerant. The units are factory tested in both heating and cooling modes. These units meet the upcoming DOE-2023 (Department of Energy) and ASHRAE (American Society ... 20 to 60 Nominal Tons. 48A2 – CV/SAV, Vertical. 48A3 - VAV, Vertical. 48A4 – CV/SAV, Horizontal. 48A5 - VAV, Horizontal. Carrier A Series Rooftop products are pre-wired and charged with refrigerant and tested in both cooling and heating modes at the factory. All models feature an industrial grade cabinet with fully hinged access panels. Fig. 1 — 48FC 04-07 Model Number Nomenclature Model Series - WeatherMaker® FC – 14.0 SEER Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 – Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 = 4 tons 06 = 5 tons 07 = 6 tons Heat Size D = Low Gas Heat E = Medium Gas Heat F = High Gas Heat access it. Carrier r ooftops have high and low pressure switches, a filter drier, and 2-in. (51 mm) standard filters. Key features: Key features are: † Single cooling stage models are available from 6 to 10 ton. † 2-stage cooling stage models are available from 7.5 to 15 ton. † EERs up to 11.1 † IEERs up to 11.7 with single speedAll WeatherMaker 3 to 6 ton units are field-convertible to horizontal airflow, which makes it easy to adjust to unex-pected jobsite complications. Comfort control Carrier’s Round Tube Plate Fin coil design helps maximize heat transfer and reliable operation. 1. Third-party trademarks and logos are property of their respective owners.CE - carrierenterprise.com6 to 23 Nominal Tons. 48LC WeatherExpert® rooftop units were designed by customers for customers. They are Carrier’s most efficient commercial packaged rooftop ever produced and have some of the industry’s highest IEER’s available. The multi stage cooling compressor logic allows for added comfort, energy savings and humidity control.View and Download Carrier 48FC M20 Series service and maintenance instructions online. Single Package Rooftop Gas Heat/Electric Cooling Unit with Puron (R-410A) Refrigerant 17.5-27.5 Nominal Tons. 48FC M20 Series air handlers pdf manual download. Also for: 48fc n20 series, 48fc m24...14 = 12.5 Ton C = Temp Standard Leak Econo w/PE(cent) ---17 = 15 Ton Vertical Only 20 = 17.5 Ton E = Enthalpy Standard Leak Econo w/Baro relief 24 = 20 Ton F = Enthalpy Standard Leak Econo w/PE(cent) 26 = 23 Ton --- Vertical Only N = Temp Ultra Low Leak Econo w/ baro relief Sensor Options P = Temp Ultra Low Leak Econo w/PE vert onlySEERs up to 14.0, IEER of 15.0. Gas efficiencies up to 82%. Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit. Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain.Carrier 48FC 6 Ton Gas/Electric 14 SEER Packaged Rooftop Unit 208/230-3-60 MED Static. Spring 2024 Preseason is going on now. ... SEERs up to 14.0, IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit;10 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU. SKU ... Add to List Share. Description. 48FCEM12A3A6-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat M = Single Circuit, Two Stage Cooling Model 12 = 10 Tons A = No Smoke or CO 2 ... Brand Carrier; Availability … 04 - 3 ton 09 - 8.5 ton 05 - 4 ton 11 - 10 ton (12.0 EER)* 06 - 5 ton 12 - 10 ton (11.5 EER)* 07 - 6 ton 14 - 12.5 ton 08 - 7.5 ton Heat Options D = Low Gas Heat E = Medium Gas Heat F = High Gas Heat L = Low NOx - Low Gas Heat M = Low NOx - Medium Gas Heat N = Low NOx - High Gas Heat S = Low Heat with Stainless Steel Exchanger CarrierFig. 1 — 48FC 04-07 Model Number Nomenclature Model Series — WeatherMaker® FC = 14.0 SEER Standard Efficiency, sizes 04-06 13.4 SEER2 Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 = Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 = 4 tons 06 = 5 tons 07 = 6 tons Heat Size D = Low Gas HeatWith so many cell phone carriers to choose from, it can be difficult to determine which one is the best fit for you. The first step in finding the right cell phone carrier is to ev...Air Conditioner Carrier 48FC Series Controls, Start-Up, Operation And Troubleshooting. ... Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages) ... Page 32 Table 15 — Quick Test, Unit Configuration and Switch Check QUICK NORMAL TEST DISPLAY STEP NO. 0 or 1 0 … Carrier Enterprise Mid-Atlantic Technical Support Site If you’re in the market for a powerful and reliable workhorse, look no further than one ton trucks. These heavy-duty vehicles are designed to handle the toughest jobs with ease, ma... Carrier There are already plenty of monopolies in big tech. Google isn't alone....GOOGL Alphabet Inc. (GOOGL) and its Google are playing scapegoat this Sunday. The tech giant is expect... 12.5 TON High Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. ... 48fc-8-14-01si; Specifications. Brand Carrier; BTU Input 250000; InvestorPlace - Stock Market News, Stock Advice & Trading Tips To bears obsessed with “trees-in-the-forest” details like the yield... InvestorPlace - Stock Market N...48FC units are single-packaged electric cooling, gas heating unit that are pre-wired and pre-charged with Puron® (R-410A) HFC refrigerant. The units are factory tested in both heating and cooling modes. Sizes 04-06 models use single-stage cooling capacity control. Size 07 models use two-stage cooling capacity control. FEATURES. New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor. Single-stage cooling capacity 04-06 models, two-stage on 07-30 models. SEERs up to 14.0, IEER of 15.2. Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit. With Weather Series Rooftop Units featuring EcoBlue™ Technology, Carrier is proving that not all rooftops are created equal. EcoBlue™ Technology includes a more compact vane axial fan, which is an industry first for packaged rooftop units, along with a simplified design that helps lower installation and maintenance costs. Turn to the experts today to learn …Revit 1 is BIM (Building Information Modeling) software, developed by Autodesk 2. It allows you to design with both parametric 3D modeling and 2D drafting elements. Building Information Modeling is a Computer Aided Design (CAD) paradigm that employs intelligent 3D objects to represent real physical building components such as walls and doors.25SCA5. Up to 15.2 SEER2 for moderate energy savings with standard comfort features. 4.5 out of 5 stars. 32 Reviews. 5 Star. 69%. 4 Star. 22%. 3 Star.Performance Features. 38AUQ Heat Pump EERs up to 11.0 and 3.5 COP. ASHRAE 90.1 Efficiency Compliant. Standard crankcase heater. Compressor vibration isolation. Low ambient temperature control. Unit performance certified in …If you’re in the market for a powerful and reliable workhorse, look no further than one ton trucks. These heavy-duty vehicles are designed to handle the toughest jobs with ease, ma...View and Download Carrier WeatherMaker 48FC04-07 installation instructions manual online. Single Package Rooftop Gas Heating/Electric Cooling Unit with Puron R-410A Refrigerant. ... The W7220 controller does not actually control the fan On single phase 48FC 3 to 5 ton units, if reduced the heat- speed or the heat output of the unit, and only ... Carrier Enterprise Mid-Atlantic Technical Support Site 15 TON High Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU. ... 48fc-16-01si; Specifications. Brand Carrier; Availability Available for ...Carrier rooftops have high and low pressure switches, a filter drier, and 2-in (51mm) filters standard. FEATURES . Single cooling stage models are available from 3 - 10 ton. Two cooling stage models are available from 7.5 - 15 ton. SEER up to 13.0 (up to 13.4 with ECM motor) EER’s up to 11.1 (up to 11.4 with ECM motor)Carrier1. Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6-ton, as appropriate. 2. Ratings are based on: » Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp. 3. All 48FC units comply with ASHRAE 90.1-2016 Energy Standard. 4. 48FC units comply with US Energy Policy Act (2005).Electric heating and electric cooling with up to 15.5 SEER2 for enhanced energy savings with enhanced comfort features. 4.5 out of 5 stars. 4.5 out of 5 stars. 4.5 out of 5 stars. 81 Reviews. 5 Star. 65% . 4 Star. 21% . 3 Star. 9% . ... Your Carrier expert will recommend the appropriate model to fit your needs. Warranty. 10-year parts limited ... SEERs up to 14.0, IEER of 15.0. Gas efficiencies up to 82%. Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit. Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain. Time to clean out your attic or garage? Forget about settling for garage sale prices. These days, online auction sites and marketplaces make it easier than ever before to sell your...12.5 TON High Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. ... 48fc-8-14-01si; Specifications. Brand Carrier; BTU Input 250000;3 to 12.5 Nominal Tons. Exclusive, new EcoBlue™ Technology was designed to improve performance and efficiency while decreasing maintenance and installation costs. The …Up to 15.8 SEER, 13.0 IEER, 12,1 EER, 8.2 HSPF, and 3.5 COP. Cooling operating range up to 125°F (52°C) and down to 30°F (-1°C) Exclusive non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain. Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt ...Carrier rooftops have high and low pressure switches, a filter drier, and 2-in (51mm) filters standard. FEATURES . Single cooling stage models are available from 3 - 10 ton. Two cooling stage models are available from 7.5 - 15 ton. SEER up to 13.0 (up to 13.4 with ECM motor) EER’s up to 11.1 (up to 11.4 with ECM motor)• SEER of 14.0 (3 to 5 Ton) • IEER of 15.0 • Meets or exceeds ASHRAE 90.1 energy efficiency levels • Rated in accordance with AHRI Standards 210/240 for sizes 04 to 06 and 340/360 for size 07 • Designed in accordance with Underwriters Laboratories Std 1995 • Listed by UL and UL-Canada14 = 12.5 Ton C = Temp Standard Leak Econo w/PE(cent) ---17 = 15 Ton Vertical Only 20 = 17.5 Ton E = Enthalpy Standard Leak Econo w/Baro relief 24 = 20 Ton F = Enthalpy Standard Leak Econo w/PE(cent) 26 = 23 Ton --- Vertical Only N = Temp Ultra Low Leak Econo w/ baro relief Sensor Options P = Temp Ultra Low Leak Econo w/PE vert only Carrier 48FC Series Controls, Start-Up, Operation And Troubleshooting (144 pages) Single package rooftop units with systemvu controls version 1.x and puronr (r-410a) refrigerant. Table of Contents General. Manual is suitable for 4 more products: 48GC Series 48GC 05 48GC 04 48GC 06. Brand: Carrier | Category: Air Conditioner | Size: 4.05 MB. Fig. 1 — 48FC 04-07 Model Number Nomenclature MODEL NUMBER RATED INDOOR AIRFLOW (CFM) 48FC*A/B04 1050 48FC*A/B05 1500 48FC*A/B06 2000 48FC*M/N07 2400 Model Series - WeatherMaker® FC – 14.0 SEER Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 – Gas Heat Packaged Rooftop … 04 - 3 ton 09 - 8.5 ton 05 - 4 ton 11 - 10 ton (12.0 EER)* 06 - 5 ton 12 - 10 ton (11.5 EER)* 07 - 6 ton 14 - 12.5 ton 08 - 7.5 ton Heat Options D = Low Gas Heat E = Medium Gas Heat F = High Gas Heat L = Low NOx - Low Gas Heat M = Low NOx - Medium Gas Heat N = Low NOx - High Gas Heat S = Low Heat with Stainless Steel Exchanger Up to 15.6 SEER, 13.0 IEER, and 12.2 EER. Gas efficiencies up to 82%. Standard cooling operating range up to 125 °F (52°C) and down to 35°F (2°C). Low ambient controllers can bring cooling operation down to -20°F (-29°C) Innovative non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center ...Brand Carrier; Availability Available for Delivery; Warehouse Availability AVON, MALD; BTU Input 250000; Compressor Stage 1; Equipment Type Commercial Packaged …Fig. 1 — 48FC 04-07 Model Number Nomenclature Model Series - WeatherMaker® FC – 14.0 SEER Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 – Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 = 4 tons 06 = 5 tons 07 = 6 tons Heat Size D = Low Gas Heat E = Medium Gas Heat F = High Gas HeatWith so many cell phone carriers to choose from, it can be difficult to determine which one is the best fit for you. The first step in finding the right cell phone carrier is to ev...Carrier 48TCED Manuals | ManualsLib. Check Details. Carrier 58UHV Product data | Manualzz. Check Details. carrier chiller data. Check Details. WeatherMaker® 48FC Single-Packaged Rooftop Units with EcoBlue™ Technology. Check Details. Carrier 14 Seer Air Conditioner - 2 Ton 14 Seer Icp Carrier Grandaire. Check …Carrier rooftops have high and low pressure switches, a filter drier, and 2-in. (51 mm) standard filters. Key features: Key features are: •Single circuit, single stage cooling model on 6 ton •Single circuit, 2-stage cooling mod-els are available from 7.5 to 10 ton. •Dual circuit 2-stage cooling stage models are available from 7.5 to 15 ton.Carrier Ton A/C-Only Rooftop Unit w/Economizer 50GCN06A1D5A0A0A0 208/230 -1. ... WeatherMaker® 48FC Single-Packaged Rooftop Units with EcoBlue™ Technology. ... Carrier® WeatherMaker® Rooftop Gas Heat Electric Cool Unit, 15 Ton, PH.48FC WeatherMaker® Single-Packaged Rooftop Units with EcoBlue™ Technology - Low Heat. Carrier 3 Ton, 13.4 SEER2 Package RTU Low Gas Heating/Electric Cooling, Direct Drive/EcoBlue ,208/1. MFR: Item: 48FCDA04A2A30A0A0. Carrier 3 Ton, 13.4 SEER2 Package RTU Low Gas Heating/Electric Cooling, Direct Drive/EcoBlue ,208/3. MFR:48KC Sizes 04 to 06 Single Packaged Rooftop Units with Gas Heat. Product Data WeatherMaker®. Gas Heat/Electric Cooling Packaged Rooftop Units. 3 to 5 Nominal Tons. 2. The Carrier rooftop unit (RTU) was designed by customers for customers. With “no-strip screw” collars, handled access panels, and more we’ve made your unit easy to install ...GAS HEATING/ELECTRIC COOLING ROOFTOP UNIT WITH PURON® REFRIGERANT COMMERCIAL ROOFTOP EQUIPMENT. GENERAL LIMITED WARRANTY STATEMENT – Carrier Corporation warrants this product against failure due to defects in material and workmanship under normal use and service, subject to the conditions, exclusions and …Carrier 48FCFM16A3A6-0A0A0 15 TON High Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU DCNE, 10 TON STAGE HEAT ROOFTOP GAS/ELECTRIC PACKAGE UNIT, VOLTAGE:460, HERTZ:60, PHASE:3, REFRIGERANT:R-22, CFM:4000, AFUE:80%, EER:9, ... WeatherMaker® 48FC Single …Same footprint as installed Carrier 3-12.5 ton rooftops back to 1989, reducing installation costs and time; Field convertible from vertical to horizontal airflow for slab mounting (sizes 04-16) Provisions for thru-the-bottom power entry capability as standard; Dedicated vertical and horizontal airflow models available (sizes 17 to 30 only)Carrier rooftops have high and low pressure switches, a filter drier, and 2-in (51mm) filters standard. FEATURES . Single cooling stage models are available from 3 - 10 ton. Two cooling stage models are available from 7.5 - 15 ton. SEER up to 13.0 (up to 13.4 with ECM motor) EER’s up to 11.1 (up to 11.4 with ECM motor)Fig. 1 — 48FC 04-07 Model Number Nomenclature Model Series - WeatherMaker® FC – 14.0 SEER Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 – Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 = 4 tons 06 = 5 tons 07 = 6 tons Heat Size D = Low Gas Heat E = Medium Gas Heat F = High Gas HeatCarrier Manuals. Air Conditioner. 48TC series. Product data. Carrier WeatherMaker 48TC Series Product Data. Carrier gas heat/electric cooling packaged rooftop 3 to 15 nominal tons. Also See for WeatherMaker 48TC Series: Service and maintenance instructions (112 pages) , Installation instructions manual (64 pages) ,Puron Refrigerant is Carrier’s unique refrigerant designed to help protect the environment. Puron is an HFC refrigerant which does ... Ratios) of 15.0 to 16.0, 12.0 to 12.5 EER, and AFUE (Annual Fuel Utilization Efficiency) ratings as high as 81%. ... ton). Coupled with the improved dehumidification associated with3 TON Medium Gas Heat 14 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. ... 48FCEA04A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat A = One Stage Cooling Models ... Brand Carrier; Availability Available for Delivery; Warehouse Availability AVON;Drawings are provided for you to assist in the creation, modification, analysis, and optimization of a building design. DXF/CAD templates are full scale 2D drawings of Carrier products. Layers are used to separate unit outlines, clearances, dimensions, and connections. Drawings are provided in AutoCAD® 1 DXF format (Drawing Interchange Format ...Performance Features. 38AUQ Heat Pump EERs up to 11.0 and 3.5 COP. ASHRAE 90.1 Efficiency Compliant. Standard crankcase heater. Compressor vibration isolation. Low ambient temperature control. Unit performance certified in …All WeatherMaker 3 to 6 ton units are field-convertible to horizontal airflow, which makes it easy to adjust to unex-pected jobsite complications. Comfort control Carrier’s Round Tube Plate Fin coil design helps maximize heat transfer and reliable operation. 1. Third-party trademarks and logos are property of their respective owners.3 to 12.5 Nominal Tons. Exclusive, new EcoBlue™ Technology was designed to improve performance and efficiency while decreasing maintenance and installation costs. The …GAS HEATING/ELECTRIC COOLING ROOFTOP UNIT WITH PURON® REFRIGERANT COMMERCIAL ROOFTOP EQUIPMENT. GENERAL LIMITED WARRANTY STATEMENT – Carrier Corporation warrants this product against failure due to defects in material and workmanship under normal use and service, subject to the conditions, exclusions and …10 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU. SKU ... Add to List Share. Description. 48FCEM12A3A6-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat M = Single Circuit, Two Stage Cooling Model 12 = 10 Tons A = No Smoke or CO 2 ... Brand Carrier; Availability …24 2 800 / 600 23000 12.0 15.0 30 2-1/2 1000 / 750 29000 12.0 15.0 36 3 1200 / 900 35400 12.5 16.0 42 3-1/2 1400 / 1050 42000 12.5 16.0 48 4 1600 / 1200 47500 12.3 16.0 60 5 1750 / 1200 57000 12.3 16.0 LEGEND dB ---Sound Levels (decibels) db—Dry Bulb SEER—Seasonal Energy Efficiency Ratio wb—Wet Bulb COP---Coefficient of PerformanceA baby carrier offers lots of benefits and should be part of your baby traveling inventory right from the start. Here is a guide to the best. We may be compensated when you click o...

NEW Direct Drive – EcoBlue™ Technology Indoor fan system uses Vane Axial fan design and electronically commutated motor with beltless design. Variable speed cooling capacity control on all models. SEER to 20.0. Gas efficiencies up to 81%. Cooling operating range up to 125 °F (52°C) and down to 0°F (-18°C). Simple living alaska new property

carrier 48fc 15 ton

CarrierAre you in the market for a half ton towable fifth wheel? If so, you’re in luck. There are plenty of great options out there to choose from. But with so many different models and f...3 TON Medium Gas Heat 14 SEER Standard EFFICIENCY Medium STATIC 208/230-1 VOLT GAS ELECTRIC RTU. ... 48FCEA04A2A3-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat A = One Stage Cooling Models ... Brand Carrier; BTU Input 90000; Equipment Type Commercial Packaged Outdoor Unit; Fan Type Vane Axial;Three carrier hvac units named finalists in consulting-specifying Carrier 48tced manuals Weathermaker® 48fc single-packaged rooftop units with ecoblue™ technology Manualslib manuals 48tc. Manual and Guide Full List. Home; ... Carrier 14 Seer Air Conditioner - 2 Ton 14 Seer Icp Carrier Grandaire. Check Details.Air Conditioner Carrier 48FC Installation Instructions. Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages) ... Page 70 FAN PERFORMANCE (cont.) Table 57 – 48TC**16 3 PHASE 15 TON HORIZONTAL SUPPLY Available External Static Pressure ...48FC WeatherMaker® Single-Packaged Rooftop Units with EcoBlue™ Technology - Low Heat. Carrier 3 Ton, 13.4 SEER2 Package RTU Low Gas Heating/Electric Cooling, Direct Drive/EcoBlue ,208/1. MFR: Item: 48FCDA04A2A30A0A0. Carrier 3 Ton, 13.4 SEER2 Package RTU Low Gas Heating/Electric Cooling, Direct Drive/EcoBlue ,208/3. MFR: The Carrier rooftop unit (RTU) was designed by customers for customers. With "no-strip" screw collars, handled access panels, and more the unit is easy to install, easy to maintain, and easy to use. Your new 3 to 6 ton WeatherMaker Carrier rooftop unit (RTU) provides optimum comfort and control from a packaged rooftop. Value-added features include: 50FCQ 04 -28, 50GCQ 04-06 Single Package Rooftop Heat Pump Units with SystemVuTM Controls Version 3.X and Puron R-410A Refrigerant Controls, Start-Up, Operation and Troubleshooting Instructions IMPORTANT: This literature covers 50FCQ 04 -28 and 50GCQ 04-06 models with SystemVu controls version 3.X... With Weather Series Rooftop Units featuring EcoBlue™ Technology, Carrier is proving that not all rooftops are created equal. EcoBlue™ Technology includes a more compact vane axial fan, which is an industry first for packaged rooftop units, along with a simplified design that helps lower installation and maintenance costs. Turn to the experts today to learn more and see how we've put a ... Carrier gas heat/electric cooling packaged rooftop 3 to 15 nominal tons (101 pages) ... Air Conditioner Carrier 48FC Installation Instructions. Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages) ...NEW Direct Drive – EcoBlue™ Technology Indoor fan system uses Vane Axial fan design and electronically commutated motor with beltless design. Two-stage cooling capacity control on all models. SEER to 16.0. Gas efficiencies up to 82%. Cooling operating range up to 125 °F (52°C) and down to 35°F (2°C).

Popular Topics